Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T00CM04007
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/21/2000 | BUILDING - FINAL | Approved | IVRS - Inspection 0000* | |
| 12/20/2000 | BUILDING - FINAL | Denied | IVRS - Inspection 0999*/1. FIX EXTERIOR GFCI OPEN NUETRAL. 2. FIRE CAULK AT O CLEARANCE FIREPLACE. 3. PAINT EXTERIOR PVC. 4. PROVIDE 3 SCREWS MINIMUM A FURNACE/HOT WATER FLUE PIPE. 5. SEAL PENETRATIONS TO ATTIC IN GARAGE. | |
| 12/19/2000 | BUILDING - FINAL | Denied | IVRS - Inspection 0999*/1. ADDRESS NOT POSTED. 2. POST TENSION SLAB NOT IDENTIFIED AT PYW. 3. DOORS LOCKED NO ACCESS TO DWELLING. 4. A REINSPECTION FEE WILL BE IMPOSED IF INSPECTIONS ARE CALLED IN PRE-MATURE. |