Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T00CM03955

Parcel: 137293780


Addresses:

5145 S FOX TROT DR

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
10/03/2000 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
09/28/2000 EXT METAL CLIPS/EXT SHEATHING Partial Approval
09/26/2000 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection CANCELLED.
09/25/2000 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/1. FRONT #4 SHEARWALLS. SEE PLAN SHEET 5A FOR HOLDOWNS THAT NEED REPLACEMENT 5 IN FRONT 1 AT BACK. 2. JACK TRUSSES FRONT MISSING H2.5S. 3. DETAIL 6/SD3 AT BEARING POST MISSING. MISSING COIL STRAP ALSO STRAPS PER PLAN ARE TO BE INSTALLED EVERY OTHER TRUSS. 4. SIMPSON HTT 22'S NOT INSTALLED. 5. SECOND FLOOR FRONT SWEST SHEARWALL MISSING E. 6. #5 SHEARWALLS AB'S 24" O.C. 7. GIRDER NOT SECURED AS PER PLAN 2ND FLOOR. 8. BLOCKS BETWEEN EVERY OTHER STUB TRUSS.