Inspection History: FRAMING
Permit Number - T00CM03951
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/25/2000 | FRAMING | Approved | IVRS - Inspection 0000* | |
10/19/2000 | FRAMING | Partial Approval | IVRS - Inspection 0000*/1. NEED BEAM SIZE AT LAUNDRY CLOSET AND SIZE OF HANGER. 2. SPACE BETWEEN NON BEARING WALL AT TRUSS. 3. BLOCK AROUND VENTS. 4. NEED TRUSS LAYOUT 5. BANG PLATE AT PLUMB. 6. BLOCK BETWEEN TRUSSES. 7. NEED F/BLOCKING. | |
10/12/2000 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/1. FIRE BLOCK NOT COMPLETE. 2. PLAN CALLS FOR HUS26 INSTEAD OF LUS26 AT TRUSS GIRDER CONNECTION. | |
10/05/2000 | FRAMING | Denied | IVRS - Inspection 0999*/1. NEED F/BLOCKING AT CHASE (SOUTH OF W/H). 2. NEED PROPER HANGERS AT TRUSSS TO GIRDER AND ALSO FROM GIRDER TO BEAM. 3. SIZE OF BEAMS NOT ON PLANS. 4. GIRDERS SHOULD HAVE SUPPORT DIRECTLY BELOW THEM. 5. BLOCKS AROUND VERTS. 6. MISSING F/D AT SHEETROCK BACKING . |