Permit: T00CM03950

Parcel: 108213260


Addresses:

1630 E RIVER RD


Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Permit Number - T00CM03950

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
04/13/2001 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection 0000*
03/19/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000$ FILL IN AT WINDOWS OK
03/16/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000$ 7TH LIFT AT ELEVATOR SHAFT
03/15/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000$ PA AT 1ST LIFT EAST SIDE NORTH END PORCH
03/14/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000$ 1ST LIFT 2ND FLOOR PORCHES EAST SIDE
03/13/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000$ PA AT EAST SIDE
03/12/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*
03/09/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*
03/08/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000$ 20' AT EAST SIDE
03/07/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*
03/06/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*
03/05/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*
03/02/2001 REINFORCED MASONRY PRE-GROUT Partial Approval PA AT 16' EAST SIDE
03/01/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*
02/28/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000$ PA AT 16' S.E. CORNER OK
02/27/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000$ 6TH LIFT AT N.E. CORNER
02/26/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000$ 6TH LIFT AT ELEVATOR SHAFT
02/23/2001 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection 0000*
02/22/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000$ PA AT 6TH LIFT AT WEST AND SOUTH SIDES
02/20/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000$ 5TH LIFT AT EAST SIDE
02/16/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000$ 4TH LIFT AT N.E. CORNER
02/15/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000$ 4TH LIFT AT NORTH WEST CORNER
02/14/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000$ PA 4TH LIFT AT WESTSIDE ELEVATOR SHAFT
02/13/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000$ PA 4TH LIFT AT SOUTH SIDE
02/12/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000$ PA 3RD LIFT EAST SIDE
02/07/2001 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection 0000* 2ND FLOOR
02/06/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000$ PA 3RD LIFT @ S. W. ENDS
02/05/2001 REINFORCED MASONRY PRE-GROUT Partial Approval 2ND LIFT N & W ENDS
02/01/2001 REINFORCED MASONRY PRE-GROUT Partial Approval 2" LIFT AT SOUTH 1/2
01/31/2001 REINFORCED MASONRY PRE-GROUT Partial Approval 1 ST LIFT AT NORTH SOUTH AND PARTIAL EAST SIDES
01/30/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVR
1ST LIFT AT WEST SIDE
01/29/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*
PA AT 2" LIFT AT NORTH AND SOUTH END
01/26/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000$
01/25/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*
01/23/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*
01/22/2001 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection 0000$
RAINED OUT
01/19/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000$
1ST LIFT AT COLS NORTH SIDE AND SOUTH SIDE
01/18/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000$
SIDE SOUTH EAST CORNER PA AT COLS EAST 1ST LIFT