Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/01/2000 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 10/30/2000 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/1. FLEX DUCTS WATER INSIDE SOME SPOTS. 2. MISSING DUCT BLOCKS AT VENTS. 3. MISSING FIRE BLOCKS. 4. DROP IN FRONT EAST BEDROOM CLOSET NOT COMPLETE. 5. NO H20 TEST 6. HD'S NOT TIGHT 7. GAS TEST OK 7. MISSING HD GARAGE 8. MISSING SHEAR WALL BLOCKING GARAGE 9. STRAP 4 X 4 AT KITCHEN BACKING FOR DRYWALL ABOVE KITCHEN SOFFIT. 10. CHECK ALL BOTTOM PLATES FOR NAILING. 11. SEE ALL ORANGE MARKS. 12. PLANS ON SITE ARE FOR STEEL FRAME. |