Permit: T00CM03912

Parcel: 107081270


Addresses:

747 W TIPTON DR

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
10/09/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
06/22/2001 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/ 1) CURVED WINDOW REQUIRES CONTINOUS AND SOLID 2 X 6 HEADER, OK TO DRY IN
06/11/2001 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*
06/04/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) 2 X 8 BLOCKING REQUIRED EACH END OF RAFTER 2) RAFTRERS SPACED IN EXCESS OF 24" AT EAST END 3) HOLD DOWNS MUST BE NAILED TO FULL LENGTH DOUBLE STUD 4) ROOF SHEATHING MUST BE INSTALLED PER PENDICTULAR TO RAFTERS, NAIL ROOF SHEATHING AT 6" ON CENTER, ENDS AND EDGES AT 12" ON CENTER IN FIELD WITH MINIMUM #8D NAILS 5) NAIL EXTERIOR SHEATHING ON ALL FRAME MEMBERS 6" AND 12"