Permit: T00CM03891

Parcel: 112021600


Addresses:

2472 E MOONRISE PL

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
10/13/2000 FRAMING Approved IVRS - Inspection 0000*
10/12/2000 FRAMING Denied IVRS - Inspection 0999*/1. HALL BATH LAV TRAP ARM MUST BE SAME SIZE AS TRAP. ALSO NEED 1/4"/FOOT PITCH. 2. PROVIDE SHEAR WALL BLOCKS AT GARAGE GAS AND ELECT AT CEILING. 3. FIRE BLOCK CHASE EAST OF MAIN ENTRY. 4. NO TEST ON GAS LINE. 5. NAIL PROTECT P. E. X. AND D.W.V. 6. SUPPORT 4 SWITCH ELECTRIC BOX TWO ENDS. 7. FIRE BLOCK M. BATH DEAD SPACE. 8. 15/D-1 NOT COMPLIED WITH. 9. M/BATH NOT PER PLAN-REVISE PLAN TO AS BUILD AND HAVE APPROVED. 10. MECHANICAL DUCTS RESTRICTED AT 5 GARAGE TOO TIGHT OF BENDS.