Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 10/13/2000 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 10/12/2000 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/1. HALL BATH LAV TRAP ARM MUST BE SAME SIZE AS TRAP. ALSO NEED 1/4"/FOOT PITCH. 2. PROVIDE SHEAR WALL BLOCKS AT GARAGE GAS AND ELECT AT CEILING. 3. FIRE BLOCK CHASE EAST OF MAIN ENTRY. 4. NO TEST ON GAS LINE. 5. NAIL PROTECT P. E. X. AND D.W.V. 6. SUPPORT 4 SWITCH ELECTRIC BOX TWO ENDS. 7. FIRE BLOCK M. BATH DEAD SPACE. 8. 15/D-1 NOT COMPLIED WITH. 9. M/BATH NOT PER PLAN-REVISE PLAN TO AS BUILD AND HAVE APPROVED. 10. MECHANICAL DUCTS RESTRICTED AT 5 GARAGE TOO TIGHT OF BENDS. |