Permit: T00CM03878

Parcel: 125170380


Addresses:

3827 E BROADWAY BL


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T00CM03878

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
04/23/2001 PLUMBING - FINAL Approved IVRS - Inspection 0000*
04/19/2001 PLUMBING - FINAL Denied IVRS - Inspection 0999* 1) MUST HAVE SEATS INSTALLED FOR WATER CLOSETS 2) PROVIDE VACUUM BREAKER AT HOSE BIBB IN REAR
3) FLOW CONTROL VENT MUST GO 6" ABOVE FLOOD RIM LEVEL 4) CONTINUOUS WASTE FOR TRIPLE COMPT. SINK MUST HAVE DIRECTIONAL FITTINGS SEE SEC. 405.4 94 UPC 5) MUST INSTALL DRAIN LINE FOR SODA DISPENSER AND BACK FLOW DISCHARGE