Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T00CM03878

Parcel: 125170380


Addresses:

3827 E BROADWAY BL


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T00CM03878

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
01/31/2001 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection 0000*
ALL CORRECTIONS MDE OK
OK TO BACKFILL
01/29/2001 PLUMBING - ROUGH, SOIL Denied CAN NOT HAVE ANY THREADED FITTINGS BELOW CONCRETE SEE SECTION 316.1.5 94 UPC
GREASE TRAP OUTLET HAS OBSTRUCTION OF FLOW THIS DRAIN LINE MUST BE 3" SEC SECTION 311.5 94 UPC
CAN NOT WEST VENT 3" GREASE TRAP INTO 2" VERTICAL DRAIN AT FLOOR SINK SEE SECTION 706.2 94 UPC. NOT TO PLAN
CAN ONLY FLAT VENT FIXTURES DUE TO STRUCTURE CONDITIONS, FLOOR SINK FOR SODA MACHINE MUST BE A CONVENTIONAL ROUGH AS PER PLAN SEE SECTION 905.3
WASTE LINE FOR FLOOR SINK AT WEST WALL EXCEEDS 135 DEGREE SEE SECTION 707.5 94 UPC
TRAP ARM FOR FLOOR SINK AT WEST WALL HAS MORE THAN 1-90 DEGREE SEE SECTION 1002.3 94 UPC
RE TEST SYSTEM