Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 10/04/2000 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 09/26/2000 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/1. CONVERTED TRUSSES REQUIRE H25'S AT EAST END. 2. CONVERTED TRUSSES DO NOT ALLOW FOR MID-SPAN DEFLECTION. SUPPLY ENGINEER APROVAL AND OR CORRECTION. 3. DOUBLE STUD NEEDED UNDER GIRDER TRUSS. 4. REAR GABLE TRUSS MUST BE TIED TO WALL BELOW. 5. PROVIDE ALTERNATE HOLDDOWN AT BATHROOM SHEAR WALL. 6. REPLACE SPLITE PLATE AT BATHROOM SHEARWALL. 7. FHA STRAP NEEDED ON CUT PLATES IN SHEAR WALL. |
| 09/12/2000 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/1. SCISSOR TRUSSES REQUIRE TC CLIP ONE END. 2. REAR GABLE REQUIRES PONY WALL, CLIPS BRACING STOPPED INSP. MANY CORRECTIONS REQUIRED. |