Permit: T00CM03848

Parcel: 141201520

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
10/04/2000 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
09/26/2000 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/1. CONVERTED TRUSSES REQUIRE H25'S AT EAST END. 2. CONVERTED TRUSSES DO NOT ALLOW FOR MID-SPAN DEFLECTION. SUPPLY ENGINEER APROVAL AND OR CORRECTION. 3. DOUBLE STUD NEEDED UNDER GIRDER TRUSS. 4. REAR GABLE TRUSS MUST BE TIED TO WALL BELOW. 5. PROVIDE ALTERNATE HOLDDOWN AT BATHROOM SHEAR WALL. 6. REPLACE SPLITE PLATE AT BATHROOM SHEARWALL. 7. FHA STRAP NEEDED ON CUT PLATES IN SHEAR WALL.
09/12/2000 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/1. SCISSOR TRUSSES REQUIRE TC CLIP ONE END. 2. REAR GABLE REQUIRES PONY WALL, CLIPS BRACING STOPPED INSP. MANY CORRECTIONS REQUIRED.