Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T00CM03759
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/22/2000 | FRAMING | Approved | IVRS - Inspection 0000* | |
11/21/2000 | FRAMING | Not ready for Inspection | ||
11/17/2000 | FRAMING | Partial Approval | IVRS - Inspection 0000* | |
11/16/2000 | FRAMING | Denied | IVRS - Inspection 0999*/1. 2X CAP ON TOP OF GLB NOT INSTALLED SEE 10/SD3. 2. 3+2X POST REQ PER NOTE 49. 3. GAS NOT IN TO F/P. 4. TUB NOT COMP. 5. FB 2ND FL SW BR BY EL BOX. 6. ELECT CANNOT BE IN RETURN AIR AND REMOVE COMUBSTION AIR BLOCK 7. 2ND FLOOR PLUMB DRAIN TEST NOT DONE. 8. WC KINK IN PEX. 9. SHEAR BLCOK #1 WALL GARAGE. |