Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 10/03/2000 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 10/02/2000 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/1. OVER BORED DBL TOP PLATE NEED UBC 232611.7. 2. SECURE GAS LINES PER UPC TABLE 12-2. 3. MECHANICAL PLATFORM NOT PER UMC 708 CONDENSATION AND REFRIGERANT NOT COMPLETE CANNOT APPROVE FRAMING UNTILL ALL TRADES COMPLETE AND APPROVED. 4. NO TEST ON WATER. |
| 09/28/2000 |
FRAMING |
|
Denied |
1. DETAIL 3/SD3 VERTICAL STRAP. 2. ANCHOR BOLTS MISSING THRU OUT SEE PLAN MISSING AT SINGLE SOLE PLATES TWO MINIMUM ANCHOR BOLT REQUIRED WITHIN 12" OF SPLICE. 3. OVER BORED SHEARWALLS THRU OUT REQUIRE 16 GA STRAP 24" LONG FILL ALL HOLES AS EPR ENGINEER'S FIX. 4. PROTECT ELECTRICAL THRU OUT. 5. STUBBED TRUSSES MISSING BLOCKS. 6. PLUMBING NEGATIVE SLOPES THRU OUT. SEVERAL INSPECTIONS HAVE BEEN MADE WITH NO PROGRESS OR SAME RESULTS. THIS JOB IS SUBJECT TO 1ST TIME REINSPECTION FEE'S. |