Permit: T00CM03587

Parcel: 118061300


Addresses:

1915 S RUFUS DR

Inspection Status: Partial Approval

Inspection History: ROOF NAILING

Date Description Inspector Results Comments
11/06/2000 ROOF NAILING Partial Approval CONTRACTOR WANTING TO DRY IN ROOF. THERE ARE SEVERAL PLANS REVISIONS STILL PENDING. CONTRACTOR CONTINUE AT OWN RISK PENDING APPROVED REVISIONS AND TRUSS CALC'S
10/17/2000 ROOF NAILING Partial Approval IVRS - Inspection 0000*/1. SHEATHIN REQUIRED AT GABLE ENDS IF AS BUILT STRUCTURE ISN'T MODIFIED. 2. INSTALL RIDGE BLOCKS NAIL THRU ROOF SHEATHIN. 3. PROVIDE PREVIOUS INSPECTION RESULTS. 4. PROVIDE APPROVED REVISION FOR I BEAM INSTALLATION BEARING ALL SCISSOR TRUSSES. 5. COMPLETE ALL TRADES BEFORE FRAMING INSPECTION.
08/29/2000 ROOF NAILING Denied 1. COMPLETE BIRD BLOCKING (SHEET AND DETAIL 1 AND 3). 2. COMPLETE RIDGE BLOCKING PER PLAN. 3. PROVIDE "X" BRACING AT BOTH ENDS AND AT 25'-0' O.C. 4. CLIP FULL BEARING GABLE END TRUSSES. 5. FLAT BLOCK OVER SPACED ROOF SHEATING. 6. PROVIDE APPROVED TRUSS CALC'S. 7. PROVIDE REVISION FOR CARPORT I BEAM STEEL WITH DETAILS FOR HOLDDOWNS AND UPLIFT BOLTS. 8. COMPLETE ROOF NAILING. NOTE: PROVIDE PAST INSPECTION RESULTS.