Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 06/25/2001 |
ELECTRIC - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000* |
| 01/09/2001 |
ELECTRIC - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection 0000*/OK TO DRYWALL MAKE UP ALL GROUNDS IN BOXES. |
| 08/29/2000 |
ELECTRIC - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection 0000*/1. UNDER SLAB OK BUT 2" CONDUIT FROM HOUSE HAVE AT LEAST 18" COVER. 2. SANITARY "T" NOT ALLOWED TO BE USED IN HORIZONTAL. W/C--REPLACE WITH A COMBINATION 3". NOTE: THIS SEPERAT STRUCTURE WILL REQUIRE A SEPERATE GROUNDING SYSTEM. I SUGGEST YOU INSTALL A UFER GROUND TO BOTTOM REBAR W/BY COPPER. |