Permit: T00CM03508

Parcel: 30503004B


Addresses:

10251 S WILMOT RD


Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Permit Number - T00CM03508

Inspection Description - MECHANICAL - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
06/13/2002 MECHANICAL - FINAL Approved IVRS - Inspection 0000*
04/16/2002 MECHANICAL - FINAL Partial Approval IVRS - Inspection 0000*
04/03/2002 MECHANICAL - FINAL Denied IVRS - Inspection 0999*KITCHEN EXHAUST HOOD MUST BE TYPE I HOOD AS PER SEC. 508. 2.) STORE DOES NOT MEET MANUFACTURERS INSTALLATION INSTRUCTIONS ON CLEARANCE FROM COMBUSTIBLE.
04/02/2002 MECHANICAL - FINAL Denied IVRS - Inspection 0999*1.) PROVIDE SECONDARY DRAIN ON AIR HANDLER ABOVE CEILING. HOOK UP CONDENSATE TO SMALL REMOT FAN COIL. 2.) PROVIDE GREASE PAN ON EXHAUST FAN ON ROOF. NEED TO SEE INSIDE OF SHAFT. 3.) FINISH HOOKING UP ELECTRICAL TO APPLIANCES. 4.) RAISE SEWER VENT 2' ABOVE EVAP COOLERS. 5.) PROVIDE MIN. 3" CLEARANCE AROUND GREASE DUCT. TYPE I HOOD REQUIRES 3" SPACING FROM WALL.