Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 01/18/2002 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 01/08/2002 |
BUILDING - FINAL |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) ALL OTHER INSPECTIONS OK EXCEPT FIREPLACE MANTLE AND SURROUND 2) GAS TAG COVER, DO NOT LIGHT FIREPLACE 3) SEE MANUAL FOR MANTLE PROJECTIONS 1 TO/RATIO TO COMBUSTIBLES 2) SIDES REQUIRE 3" FROM OPENING |
| 01/04/2002 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) WATER HEATER SINGLE WALL VENT MUST HAVE 6" CLEARANCE TO COMBUSTIBLE MATERIAL 2) PROVIDE FRIEPLACE INSTALLATION MANUAL FOR CLEARANCE TO COMBUSTIBLE DATA 3) UNSAFE FURNACE-VENT NOT PROPERLY CONNECTED 4) ALL ELECTRIC OUTLETS IN BATHROOM MUST BE GFCI PROTECTED 5) PROVIDE ANOTHER GAS PRESSURE TEST FOR ADDED LINE TO FIREPLACE 6) PROVIDE GAS SHUT OFF VALVE FOR FIREPLACE |
| 12/28/2001 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) ADDRESS NOT POSTED 2) PRV AT WATER HEATER NOT HOOKED UP TO DRAIN PROPERLY 3) FIREPLACE INSTALLATION NOT COMPLETE NOT ON PERMIT/ADDITION |