Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
01/18/2002 BUILDING - FINAL Approved IVRS - Inspection 0000*
01/08/2002 BUILDING - FINAL Partial Approval IVRS - Inspection 0000*/ 1) ALL OTHER INSPECTIONS OK EXCEPT FIREPLACE MANTLE AND SURROUND 2) GAS TAG COVER, DO NOT LIGHT FIREPLACE 3) SEE MANUAL FOR MANTLE PROJECTIONS 1 TO/RATIO TO COMBUSTIBLES 2) SIDES REQUIRE 3" FROM OPENING
01/04/2002 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) WATER HEATER SINGLE WALL VENT MUST HAVE 6" CLEARANCE TO COMBUSTIBLE MATERIAL 2) PROVIDE FRIEPLACE INSTALLATION MANUAL FOR CLEARANCE TO COMBUSTIBLE DATA 3) UNSAFE FURNACE-VENT NOT PROPERLY CONNECTED 4) ALL ELECTRIC OUTLETS IN BATHROOM MUST BE GFCI PROTECTED 5) PROVIDE ANOTHER GAS PRESSURE TEST FOR ADDED LINE TO FIREPLACE 6) PROVIDE GAS SHUT OFF VALVE FOR FIREPLACE
12/28/2001 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) ADDRESS NOT POSTED 2) PRV AT WATER HEATER NOT HOOKED UP TO DRAIN PROPERLY 3) FIREPLACE INSTALLATION NOT COMPLETE NOT ON PERMIT/ADDITION