Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 10/26/2000 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 10/25/2000 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/1. RANGE HOOD WEATHER CAP NOT INSTALLED. 2. OPEN CABLE TRENCH COVER. 3. INSTALL APPROVED CLEAN OUT CAPS THREADED. 4. SEAL EXTERIOR WALL PENETRATION AT WATER HEATER T AND P LINE. 5. GFCI OUTLET REQUIRED WITHIN 24" OF RT SIDE OF SINK 6. NEED INSULATION INSTALLATION CERTIFICATION LETTER. |
| 10/24/2000 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0950*/ABS PLASTIC VENTS MUST BE PAINTED WITH LATEX PAINT. 2. NO POWER ON FACILITY. 3. W/H NOT WIRED. 4. OUTSIDE HOSE BIBS REQUIRED ANTI SIPHON VALVE. |