Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 09/29/2000 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 09/28/2000 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ADDRESS MUST BE POSTED AT ALL SITES. |
| 09/27/2000 |
FRAMING |
|
Denied |
IVRS - Inspection 0160*/1. FIRESTOP UNDER WATER HEATER PLATFORM. 2. VENT TUBE IN HALL BATH, STRAP AT ROOF JACK. 3. SCISSOR TRUSSES REQUIRE ONE END TO HAVE A TRUSS CLIP WITH SLOTTED HOLES TO ALLOW FOR TRUSS DEFLECTION. THE TRUSSES HAVE A2.5 FIXED CLIPS AT BOTH ENDS. 4. THE LARGE RETURN AIR REGISTER REQUIRES BLOCKS AND SCREWS. 5. REMOVE DUCT TAPE SUPPORT FROM DRYER VENT AND REPLACE W/PLUMBERS STRAP. |