Permit: T00CM03435

Parcel: 141195930

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
09/29/2000 FRAMING Approved IVRS - Inspection 0000*
09/28/2000 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ADDRESS MUST BE POSTED AT ALL SITES.
09/27/2000 FRAMING Denied IVRS - Inspection 0160*/1. FIRESTOP UNDER WATER HEATER PLATFORM. 2. VENT TUBE IN HALL BATH, STRAP AT ROOF JACK. 3. SCISSOR TRUSSES REQUIRE ONE END TO HAVE A TRUSS CLIP WITH SLOTTED HOLES TO ALLOW FOR TRUSS DEFLECTION. THE TRUSSES HAVE A2.5 FIXED CLIPS AT BOTH ENDS. 4. THE LARGE RETURN AIR REGISTER REQUIRES BLOCKS AND SCREWS. 5. REMOVE DUCT TAPE SUPPORT FROM DRYER VENT AND REPLACE W/PLUMBERS STRAP.