Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/29/2000 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 11/21/2000 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/1. "B" VENT PIPE AT MECHANICAL PLATFORM MUST BE AT LEAST 1" AWAY FROM WOOD AND OTHER COMBUSTIBLES. 2. SOME JOIST HANGERS NOT FULLY NAILED (ABOVE BACK WALL OF GARAGE) 3. A35'S NOT PROPERLY INSTALLED ON LEDGER AT INTERIOR BEARING WALL. 4. BLOCK ATTENDS OF MECHANICAL PLATFORM FOR PERIMETER NAILING OF DRYWALL. 5. FLEX DUCT MUST BE SUPPORTED AND FULLY EXTENDED. 6. ON ALL SIMPSON ANCHORS AND HANGERS ALL ROUND NAIL HOLES MUST BE USED (ALL DIAMOND HOLES ARE OPTIONAL). 7. WALL CHANNELS MUST BE FIRE BLOCKED AT CEILING LEVEL. |