Permit: T00CM03401

Parcel: 126133390


Addresses:

4602 E MONTECITO ST

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
09/19/2000 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection 0000*
09/14/2000 ELECTRIC - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*/1. USE #8 CU. TO FEED SUB PANEL. 2. NEED TWO KIT. COUNTER TOP CIRCUITS. 3. 15 AMP FOR REFRIDGE. 4. TAPE RANGE WIRE INSULATION COT.
09/12/2000 ELECTRIC - INTERMEDIATE Not ready for Inspection
09/08/2000 ELECTRIC - INTERMEDIATE Not ready for Inspection 1. NEED DUCT SIZE ON PLAN, METAL DUCT CONNECTIONS NEED TO BE RIBBED WHERE THEY CONNECT. SO THE FLEX WON'T COME OFF, USE A PLASTIC STRAP TO SECURE PLUS TAPE. 2. MISSING OUTLETS AT THE KITCHEN SEE YOUR PLAN. 3. FUSE ONLY APPROVED FAN BOX, SECURE ROMEX SIX INCHES FROM EACH BOX TO WALL. 4. SUB PANEL FEED WITH 30 AMP. WIRE TOO SMALL YOU NEED TO RETHINK THE WAY YOUR WIRING THIS ADDITION. 5. PLUMBING NOT PER PLAN. 6. ELECT. OVEN REQS. A 50 AMP CIRCUIT WITH 3 INSULATED WIRES AND ONE BARE WIRE= #8-3 WITH GROUND.