Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/31/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 01/24/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/1. PROVIDE JOIST REPAIR LAUNDRY. 2. NAIL PROTECT WIRES MUD CLOSE. 3. WALL ANCHORS MISSING NUTS. 4. JACCUZZI TUB MUST HAVE METAL PLUMBING BONED TO PUMP WITH #8 BOND WIRE. 5. NAIL PROTECT NMC. CONDUIT BY SUB PANEL. 6. LOW GAS PRESSURE TEST. 7. SUB PANELS REQUIRE ISOLATED NEUTRAL BARS. 8. BOND WATER AND GAS LINE W/CONNECTION EXPOSED. |
| 01/09/2001 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/UNDER FALSE ROOF OK PORCH SHEATHING OK. OVER ROOF NOT IN. |