Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 05/09/2001 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 05/08/2001 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ UFER GROUND WAS NOT INSTALLED, INSTALL TWO GROUND RODS 6' APPART CONNECTED TO PANEL WITH #4 WIRE |
| 02/15/2001 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/1. TRIM C.U. TO GRADE. 2. LIGHT FIXTURE MISSING BARE WIRES. 3. PROVIDE PROOF OF INSPECTION APPROVAL FOR ALL OPEN ITEMS BELOW. 4. SERVICE PANEL (ELECT) REQUIRES NON WATER BOND LABLE. 5. BARE WIRES EAST SIDE OF HOUSE. 6. WATER HEATER VENT "B" PLUGGED WITH TAPE. 7. GARAGE PERSONNEL DOOR MUST BE SELF CLOSING. |