Permit: T00CM03314

Parcel: 118038040

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
09/26/2000 FRAMING Approved IVRS - Inspection 0000*
09/25/2000 FRAMING Denied IVRS - Inspection 0999*/ALL FRAMING ITEMS NOT COMPLETE FROM LAST TO INTERMEDIATE INSPECTIONS ON 9/21 AND 9/22
09/22/2000 FRAMING Denied IVRS - Inspection 0999*1. SEE PREVIOUS INSPECTION 9/21/00 #4, 6, 7. 2. MISSING 1/2 AB'S THROUGH OUT HOUSE. 3. PROVIDE SPARK ARREST AT ATTIC FURNACE. 4. REPAIR SOLE PLATE AT FRONT DOOR. 5. BACK PATIO POST/BEAM CONNECTIONS STILL NOT BOLTED.
09/21/2000 FRAMING Partial Approval 1. SUPPORT AND SECURE OVERFLOW CONDENSATION LINES. 2. PROVIDE DRAFT STOPS FIRE BLOCKS TWO LOCATIONS. 3. SECURE GAS LINE HORIZONTALLY AT IN ATTIC. 4. PROVIDE 1/4 INCH SLOPE AT WASTE ARM HALL BATH. 5. PROTECT ABS, ROMEX. 6. LOOSE SOLE PLATE HALL BATH. 7. PROVIDE BACK FLOW DAMPER FOR EXHAUST FAN.