Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T00CM03296
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/16/2000 | FRAMING | Approved | IVRS - Inspection 0000* | |
11/13/2000 | FRAMING | Partial Approval | IVRS - Inspection 0000*/1. REVISION R1 AND R2 NOT APPROVED BY C.O.T. REVISION R1 NOT CORRECT FOR AS BUILT. REVISION CALLS FOR 2-3/4" PLYWOOD AT LEDGER (CURVED) AS BUILT USED 2-3/4" O.S.B. 2. PROVIDE GAS TEST. 3. REMOVE INSULATION FROM FURNACE/HOT WATER FLUES FOR INSPECTION. 4. REMOVE INSULATION FROM AROUND REVISION DETAIL R-2 FOR INSPECTION. 5. PROVIDE VTR FOR EJECTOR IN BASEMENT. NOTE: HOUSE HAS 4 WATER CLOSETS (4 FULL BATHS) WILL NEED TO VARIFY HOUSE ROUGHED WITH 4" ABS. CURRENTLY 3" RISERS AT EXTERIOR CLEAN OUT. OK TO SHEET ROCK OTHER THAN THESE AREAS FOR INSPECTIONS. | |
11/06/2000 | FRAMING | Denied | 1. BLOCK ALL MECHANICAL 3 SIDES. 2. CONDENSATION LINE OUT OF WALL. 3. REMOVE INSULATION FROM FURNACE AREA AND DO NOT INSULATE UNTIL INTERMEDIATE INSPECTIONS ARE APPROVED. 4. PROVIDE BANG PLATES FOR T AND P LINE. 5. SEAL CONCRETE AT LAUNDRY. 6. COMPLETE WATER CLOSET RINGS. 7. REMOVE INSULATION FROM ALL EXHAUST FAN DUCTING FOR INSPECTION. 8. ELECTRIC NOT COMPLETE AT WEST (MASTER?) BEDROOM. 9. PROVIDE ACCESS PANEL FOR JACUZZI. 10. PROVIDE EXPLANATION FOR CAP VENT LINE AT MASTER SHOWER. 11. SECURE GAS LINE AT TOP OF STAIRS. 12. PROVIDE MIN. 10LBS. AIR TEST TO GAS LINES. 13. NO CONDENSATION PROVIDED FOR LOWER A/C. 14. PLAN REVISIONS, PLANS, PERMITS, NOT ON SITE. 15. TUBS NOT GROUTED. 16. PROVIDE WATER TEST TO 2ND STORY ABS TO 42". PLEASE MAKE ARRANGEMENTS FOR PLUMBING CONTRACTOR TO BE AT NEXT INTERMEDIATE. |