Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: ROOF NAILING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/09/2000 |
ROOF NAILING |
|
Approved |
IVRS - Inspection 0000* |
| 11/02/2000 |
ROOF NAILING |
|
Denied |
IVRS - Inspection 0999*/1. MECH SUPPLY DUCT RESTRICTED BY ONELAND COMBUSTION AIR DUCT. 2. NO MECHANICAL PLAN ON SITE. 3. W/H COMBUSTION AIR TOO SMALL. MUST HAVE 100 SQ IN HIGH AND LOW. 4. CANNOT APPROVE FRAME UNTIL ALL TRADES ARE COMPLETE. 5. SOME H2.5 CLIPS ON CARPORT NOT NAILED. 6. O.S.B SHEATHING OVER ENTRY INSTALLLED WITH STRANDS IN WRONG DIRECTION MUST BE PERPENDICTULAR TO TRUSSES. |