Permit: T00CM03284

Parcel: 113101640


Addresses:

4827 E WAVERLY ST

Inspection Status: Approved

Inspection History: ROOF NAILING

Date Description Inspector Results Comments
11/09/2000 ROOF NAILING Approved IVRS - Inspection 0000*
11/02/2000 ROOF NAILING Denied IVRS - Inspection 0999*/1. MECH SUPPLY DUCT RESTRICTED BY ONELAND COMBUSTION AIR DUCT. 2. NO MECHANICAL PLAN ON SITE. 3. W/H COMBUSTION AIR TOO SMALL. MUST HAVE 100 SQ IN HIGH AND LOW. 4. CANNOT APPROVE FRAME UNTIL ALL TRADES ARE COMPLETE. 5. SOME H2.5 CLIPS ON CARPORT NOT NAILED. 6. O.S.B SHEATHING OVER ENTRY INSTALLLED WITH STRANDS IN WRONG DIRECTION MUST BE PERPENDICTULAR TO TRUSSES.