Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 05/09/2002 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 05/01/2002 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*CO MISSING AT FLOOR SINK IN MECH ROOM PLEASE SEE INSP AS OF 12-14-01 SEE PLAN P-1 |
| 12/14/2001 |
PLUMBING - FINAL |
|
Not ready for Inspection |
OK FOR TEMP C OF O SUBJECT TO OTHER INSP SEC STEVE L FOR GAS CARD.LAV H.C. 34" PLEASE VACUUM BREAKER ON HOSE COMPLETE ROOF DRAINS 3" VENT FLASHING ALSO 2" VENT CO END OF RUN AT FLOOR SINK CO TO GRADE. |
| 12/10/2001 |
PLUMBING - FINAL |
|
Partial Approval |
IVRS - Inspection 0000*TEMP C OF O PLEASE SEE STEVE LONG. SEE INSP AS OF 12-4-01 |
| 12/04/2001 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*1.) TRAP PRIMER? NOT INSTALLED PROPERLY 2.) SIDE CLEARENCE AT H.C W/C CODE CALLS FOR 18" 3.) SIDE CLEARENCE AT W/C 15" AS PER CODE 4.) PROVIDE UNION AT EXPASSION TANK & ANCHOR TANK. 5.) SEC PLAN FOR LOCATION OF ALL CO. |