Permit: T00CM03232

Parcel: 114469370

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
12/18/2000 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection 0000*
BLDG DRAIN HAS BEEN RAISED TO MANTAIN 45 DEGREE FROM BOTTOM OF FOOTER
OK TO BACKFILL TRENCH
12/04/2000 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999*
MUST HAVE APPROVED DRAWING ON BACKFILL OF TRENCH IN REFERANCE TO SECTION 131.3 94 UPC
SOIL WATER TEST FOR ROUGH PLDG IN BLDG OK
SOIL WATER TEST FOR RAN LEADERS OK
OK TO BACKFILL BLDG SEWER
HCS CONNECTION AND BLDG SEWER WATER TEST OK
12/01/2000 PLUMBING - ROUGH, SOIL Cancelled IVRS - Ri canceled
11/28/2000 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999*
MUST REMOVE 4" TEST TEE AT HCS CONNECTION THERE CAN BE NO THREADED FITTINGS UNDER GROUND
CAN NOT USE TWO WAY C.O. FITTING WITH A EXTENSION ON IT. TWO WAY C.O. MUST BE DIRECTION AL FITTINGS
BLDG. DRAIN IS TO CLOSE TO STRUCTURE FOOTING SEE SECTION 131.3 94 UPC