Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 02/28/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 02/14/2001 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 02/13/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/1. GABLE ENDS TRUSS NEEDS CONTINOUS SUPPORT AT TOP PLATE. 2. HANGER FOR GLU LAM BEAM NOT APPROVED TYPE 3. AT J-BOX BOND THE METAL BOX 4. NEED FULL SIZE 3/4" TEMP. PRESS RELIEF LINE FOR H20 HEATER THRU ROOF WITH PET COCK. 5. NEED COMB/RELIEF DUCTS. 6. P.V.C. H20 LINES INSIDE BLDG. MUST BE OF APPROVED MATERIAL 7. MOVE ROMEX AWAY FROM H20 HEATER FLUE. 8. CONNECT EXHAUST FAN DUCTS 9. NEED GAS LINE PRESS TEST. 10. GROUT BLOCK CONNECT EXHAUST FAN DUCTS. 11. BLOCK 3 SIDES OF ALL MECH DUCTS (DIFUSSERS). 12. MAKE SURE BATHROOM OUTLETS ARE ON A SEPARATE 20 AMP CIRCUIT WILL CHECK AT FINAL. 13. TRUSSES CUT OR BORED (CALL TRUSS MANUFACTURE FOR REPAIR (DON'T CUT OR NOTCH TRUSSES.) 14. UNCOVER TOILET FLANGE. 15. SMOKE DETECTOR? 16. WHERE VENT FOR TOILET AND SHOWER MEET REMOVE VENT "T" FROM HORIZ USE VERT. OR USE DOUBLE SAN "T" |