Permit: T00CM03174

Parcel: 136240380


Addresses:

6818 E 39TH ST

Inspection Status: Approved

Inspection History: BUILDING PRE-SLAB

Date Description Inspector Results Comments
11/15/2000 BUILDING PRE-SLAB Approved IVRS - Inspection 0000*
11/07/2000 BUILDING PRE-SLAB Denied 1. SOIL LINES FOR ADDITION NOT DONE TO CODE WRONG FITTINGS USED, SAN "T" LYING FLAT SHORT 90 1/4 BEND USED ON TOILET BEND AT FLANGE FLAT VENTED IN PROPERLY, PLUMB CONVENTION NO REASON TO FLAT VENT, ONE 2" RISER SUFFICIENT FOR DBL LAV. DON'T USE NO HUB BANDS AT CAST IRON.
10/25/2000 BUILDING PRE-SLAB Denied IVRS - Inspection 0999*