Permit: T00CM03154

Parcel: 123071900


Addresses:

2415 E HELEN ST

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
06/18/2001 BUILDING - FINAL Approved IVRS - Inspection 0000*
06/14/2001 BUILDING - FINAL Not ready for Inspection IVRS - Inspection 0000*
06/12/2001 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) NO ADDRESS POSTED MUST BE ON BUILDING IN 3" HIGH NUMBERS ON CONTRASTING BACKGROUND VISIBLE, ADDRESS 2415 MUST BE ON HOUSE NOT AT CURB SIDE 2) UNTREATED WOOD CANNOT BE IN CONTACT WITH SOIL OR MASONARY VENT FRAMES
06/01/2001 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) NO ADDRESS POSTED, MUST BE ON BUILDING IN 3" HIGH NUMBERS ON CONTRASTING BACKGROUND VISIABLE 2) CRAWL SPACE MUST BE PROTECTED WITH 1/4" MESH GRILL COVER 3) CLOTHES DRYER MUST HAVE 4 PROWN PLUG 4) ALL PLANS AND PRIOR INSPECTION REPORTS AND INSPECTION CARD REQUIRED AT FINAL INSPECTION 5) INSULATION AND STUCCO INSTALLATION CERTIFICATES REQUIRED, STUCCO ON SITE 6) DRIVE GROUND RODS FLUSH TO GRADE 7) ROOF TOP ATTIC ACCESS REQUIRES WEATHER PROOF COVER 8) 2 EACH A/C ELECTRIC DISCONNECTS SUPPORTED BY A SINGLE CONDUIT-NOT ALLOWED-INSTALL AN ANTI ROTATION BRACE
04/23/2001 BUILDING - FINAL Denied IVRS - Inspection 0999*/NO ADDRESS POSTED, NO ACCESS