Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 09/18/2000 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000*/1. NAIL OFF JOINT NORTH SIDE 2ND ROW FROM TOP. 2. NAIL PARA PETS WALL 3 CAR GARAGE PERIMETER. |
| 09/15/2000 |
EXT METAL CLIPS/EXT SHEATHING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 09/13/2000 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/1. NEED 3 CAR GARAGE PLAN (2) NEED TRUSS DRAWING. 3. MISSED NAILING ON ROOF. 4. FINISH SCRUPPERS. 5. DBL TRUSS NAILING, B LATERAL BRACING. 6. MAIL STUD NORTH WALL FRONT BEDROOM, FLAT ROOF TO HIP SECTION. |