Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T00CM03078
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/20/2000 | FRAMING | Approved | IVRS - Inspection 0000*/FRAMER HANDLED PICK UPS FOR MECHANICAL | |
10/18/2000 | FRAMING | Denied | IVRS - Inspection 0999*/1. ALL FIRE WALL FRAMING MIN. 16 O.C. 2. BLOCK RETURN AIR 3 SIDES, ALSO VENTS. 3. PROVIDE 1/2" AB. AT S.W. #3. 4. PROVIDE 1" AT VENT TO COMBUSTIBLES. 5. COMPLETE WIRING TO EXHAUST FANS. 6. DRYER DUCT NOT THROUGH ROOF. 7. CLIP 3 POINT BEAR TRUSSES. 8. COMPLETE ELECTRIC TO ISLAND. 9. DBL STUD GIRDER AND CLIPS. 10. TSI NOT CLIPPED AT INTERIOR BEARING. |