Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 06/18/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 06/06/2001 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) CLOSET FLANGE NEEDS 15" TO CENTER LINE 2) KITCHEN SINK 6" ABOVE FLOOD RIM BEFORE GOING HORIZONTAL WITH VENT 3) LEAK IN WATER LINE COPPER 4) SHOWER NEEDS SHWOER PAN INSTALLED AND CENTER TRAP MUD JOB INSTALL ALL FLASHING 5) BLOCK AT BATH WINDOW 4" VENT 6) STRAP ALL PLUMBING, NEED FHA STRAP STUD CUT SIX HOLE EACH SIDE 7) GAS TEST OK 8) NEED DRAIN FOR SOFTNER (AIR GAP REQUIRED IF DRAINING INTO SEWER) |