Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/27/2000 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 11/13/2000 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/REMOVE INSULATION AND SHEET ROCK FROM AREAS THAT NEED INSPECTIONS FROM PREVIOUS INTERMEDIATES. NO PLANS OR PERMITS. |
| 11/08/2000 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/1. PROVIDE CONDENSATION LINE 2ND FLOOR. 2. SMOKE DET. NEEDS TO BE 36" FROM ANY AIR DUCT. 3. PROVIDE FHA STRAP AT FURNACE VENTS 2ND FLOOR. 4. ADD CRIPPLE AT FLOOR JOIST AT STAIRS. 5. PROVIDE STRUCTURAL SUPPORT UNDER STRINGERS. 6. PROVIDE POSITIVE CONN. AT POST TO BOT. PLATE. 7. BLK AND NAIL AT PORCH BEAM SD-3. 8. EXT WALL AT LIV. RM REQUIRES SD4-?. DETAIL 1/SD4 NOT COMPLETE PLAN DOES NOT SLEARLY INDICATE CONNECTIONS PROVIDE ENGINEERS EVALUATION FOR CONNECTIONS. |
| 11/06/2000 |
FRAMING |
|
Not ready for Inspection |