Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T00CM03014

Parcel: 112021460


Addresses:

3673 N SUNTERRA CT

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
11/20/2000 BUILDING - FINAL Approved IVRS - Inspection 0000$
11/17/2000 BUILDING - FINAL Partial Approval IVRS - Inspection 0000*/1. KITCHEN COUNTER REQUIRES GFCI OUTLETS WITHIN 24" OF EITHER SIDE OF SINK PER 1999 N.E.C. SECTION 210-54,C,1. THIS KITCHEN COUNTER ACTS AS A DIVIDING WALL BETWEEN KITCHEN AND DINING ROOM AND FACES WEST. THE NORTH WALL IS PERPENDICULAR TO COUNTER AND IS EXTERIOR WALL. THE SOUTH SIDE OF COUNTER IS A FLOOR TO CEILING COLUMN. THE ENTIRE LENGTH OF COUNTER HAS A 3 3/4" BACK SPLASH. THE PLAN CALLS FOR 2 EACH GFCI OUTLETS ON ALTERNATE CIRCUIT ON EITHER SIDE OF SINK. PRESENTLY THE TWO INSTALLED GFCI OUTLETS ARE ON THE SAME CIRCUIT.
11/16/2000 BUILDING - FINAL Denied IVRS - Inspection 0920*/HOUSE LOCKED NO ACCESS THIRD FAILURE.
11/08/2000 BUILDING - FINAL Denied IVRS - Inspection 0999*/NO CHANGE FROM PRIOR.
11/01/2000 BUILDING - FINAL Denied IVRS - Inspection 0950*/1. MULTI WIRED BRANCH CIRCUITS ON DISHWASHER/DISPOSAL, BATH GFI/WASHER KITCHEN GFI AND FRIDGE AND ONE UNLABLED. SEE ARTICLE 100 1999 NEC. AND COMPLY WITH 210-4. 2. ELECTRIC SERVICE PANEL REQUIRES ALL CUTLER HAMMER CIRCUIT BREAKERS. SEE PANEL LABLE. 3. LABLE ALL CIRCUITS IN PANEL. 4. ELECTRIC PANEL REQUIRES 1' NON WATER BOND LABLE 5. FURNACE GAS LINE LOOSE. 6. FIRE PROOF CAULK GAS LOG LIGHTER FIREPLACE PENETRATION. 7. GFCI OUTLETS REQUIRED WITHIN 24" OF EITHER SIDE OF KITCHEN.