Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T00CM02997

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
09/20/2000 FRAMING Approved IVRS - Inspection 0000*
09/14/2000 FRAMING Not ready for Inspection IVRS - Inspection 0000*/1. NEED FURN/H20 HEATER FLUE. 2. LOW GAS TEST PRESS 3. BACKING A TUB. 4. H20 LINE TOP PLATE FRONT BATCH LAV. FEED INSULATOR MISSING AT HOME. 5. MOVE PEX AWAY FROM CAN LIGHT ENTRY TO FRONT BATH. 6. 1/2" PEX INSULATOR BUSHING REAR BATCH HAVE COME LOOSE. 7. REAR BATH EXHAUST FAN NOT SECURED. 8. ROMEX IN REAR BEDROOM AND CLOSET AND GARAGE, FINISH WIRING AND TERMINATE WIRE IN BOXES 9. REAR BATH DIVERTER VALVE ISOLATE COPPER FROM METAL STUD.