Permit: T00CM02965

Parcel: 11708365B


Addresses:

949 S 8TH AV #01

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
02/28/2001 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection 0000*
11/17/2000 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/1. BLOCK 3 SIDES ON MECH DUCT. 2. INSIDE WALL OK OK TO SHEET ROCK. 3. ELECTRICAL EXCLUDES NORTH AND SOUTH WALLS.
11/01/2000 ELECTRIC - INTERMEDIATE Denied SEE PLUMBING NOTE #12 ALL INTERIOR COPPER TO BE TYPE "L" HARD
SOUTH UNIT WASHER
MAKE SURE TRAP IS INSTALLED AT LEAST 6" AFF OK
MAKE SURE STAND PIPES NO LONGER THAN 30" OK
CLEAN OUTS ARE TO BE INSTALLED ON VERTICAL PIPING
ABS MUST BE SUPPORTED MAXIMUM FOUR FEET ON HORIZONTAL (VENTS)
I WOULD LIKE TO SEE THE APPROVED LISTING FOR SHOWER DRAINS
CODE REQUIRES A WATER TEST FOR DWV PIPING UP TO 42" AFF
NOTE # ONCE YOU CUT IN FITTINGS AND PIPE ROUGH IN TEST IN NEGATED
COPPER TO BE WRAPPED WHERE PASSING THROUGH MASONARY