Inspection Status: Denied
Inspection History: FRAMING
Permit Number - T00CM02936
Inspection Description - FRAMING
Inspection Status - Denied
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/19/2000 | FRAMING | Denied | IVRS - Inspection 0999*/NOTE: GAS LINE AND W/H VENTS NOT IN. 1. WINDOWS WITHIN 24" OF BACK DOOR HAVE TO BE SAFETY GLAZED. 2. 3RD PLIGHT OF STAIRS RISERS EXCEED 8". OK TO INSULATE AND DRYWALL EVERYTHING EXCEPT GAS LINE RUNS AND STAIRS GOING TO ROOF. | |
09/22/2000 | FRAMING | Denied | IVRS - Inspection 0999*/HD2A MISSING AT SOUTH ENTRY. 2. ANCHOR BOLTS NEEDED AT PLATE ENDS. 3. CLIP RAFTERS WEST SIDE CENTER. 4. NOT CHECK OK ON 2ND FLOOR DWV. 5. PLUMBING VENTS AND DRAINS NEED CORRECTING AT 2ND FLOOR STAIRWELL AND 1ST FLOOR WEST WALL. |