Permit: T00CM02933

Parcel: 116093240

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
01/24/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
10/19/2000 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/EXPOSE P. B. V.'S AT FRONT PORCH POST BASES,
10/17/2000 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*
10/13/2000 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/SHEARS NOT COMPLETE.
09/19/2000 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*ALL ALTERNATE BRACED WALL PANELS NOT INSTALLED PER UBC 2326.11.4. CURRENTLY PANELS ARE 11'-0" TO 16'-0" FROM SOLE PLATE TO ROOF SHEATING. HOLDDOWNS INSTALLED INCORRECT NOT AT EACH PANEL ENDS. CLIPPING NOT COMPLETE. THROUGH OUT. SUPER STOPPED INSPECTION AT THIS TIME.