Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T00CM02790
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/18/2000 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection 0000* SOI8L WATER TEST OK P.O.C. OF NEW BLDG. DRAIN TO EXSISTING BLDG DRAIN OK OK TO BACKFILL DRAIN |
|
09/14/2000 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection 0999* LEAKING COUPLING, RE TEST SYSTEM |
|
09/13/2000 | PLUMBING - ROUGH, SOIL | Partial Approval | SOIL WATER TEST OK OK TO BACKFILL | |
09/07/2000 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection 0999* MUST PROVIDE TEST UP TO BLDG MUST EXPOSE ALL OF BLDG SEWER SEE SECTION 103.5.1.3 94 UPC ON GRADE FOR BLDG SEWER MUST BE IN 1/4" PER FT ON 3" WASTE SEE SECTION 708.0 94 UPC |
|
08/31/2000 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection 0000* WASTE AND VENT SYSTEM IN BLDG OK HCS SEWER TAP AT MAIN OK MUST TEST REMAINDER OF 3" FROM OC..O TO HCS TAP |
|
08/30/2000 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection 0999* HORIZONTAL VENT MUST BE 6" ABOVE FLOOD RIM LEVEL BLDG DRAIN MUST HAVE GRADE C.O. OUTSIDE OF BLDG WITHIN 5' FLOOR DRAINS AT WEST AND NORTH WALL MUST BE ROUGHED IN CONVENTIONAL RE TEST SYSTEM |