Permit: T00CM02780

Parcel: 133372070

Inspection Status: Not ready for Inspection

Inspection History: FRAMING

Date Description Inspector Results Comments
10/18/2000 FRAMING Not ready for Inspection IVRS - Inspection 0000*
10/16/2000 FRAMING Denied IVRS - Inspection 0999*/1. NO PRESSURE TEST H20 LINES. 2. CONNECT WIRING TO EXHAUST BATH FAN. 3. MINIMUM 1" CLEARANCE FLUE PIPE TO COMBUSTIBLES. 4. FIREBLOCK TOP CHORD TRUSS AT GARAGE INTO UPSTAIRS BEDROOM. 5. SECURE DUCT WORK AWAY FROM ATTIC FURNACE. 6. BLOCK MIN. 3 SIDES ALL MECH DUCTS. 7. COMPLETE FIREPLACE CHAISE TERMINATION. 8. FIREPLACE NOT INSTALLED UPSTAIRS.