Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T00CM02771

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
10/16/2000 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*/1. BLOCK AT TJI REAR PORCH
10/06/2000 EXT METAL CLIPS/EXT SHEATHING Denied SEE LAST INSP. MISSING P.A.'S
09/29/2000 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/1. SHEAR PANEL NAILING IS 16" O.C. 2. N/E CORNER MISSED RAFTER. 3. REAR COLUMNS NOT COMPLETE. 5. H.D.'S NOT DONE. 5. SEE POP OUT ROOF FRAMING A/BOLTS AT COL.
09/26/2000 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/1. MISSING HORIZ/VERTICAL NAILING SHEAR MAX 16" O.C. VERTICAL 2. THREE HD'S AT REAR NOT NAILED 3. MISSING WIND BRACES. 4. MISSING TRIM STUDS UNDER BEAM HEADER BATHROOM DBL STUDS UNDER DBL GIRDERS.