Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T00CM02745
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/07/2000 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection 0000* | |
10/26/2000 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection 0999* 10/26/00 GROUND SCREW TO HAVE FULL SURFACE CONTACT NOT ON LOCKNUT NEED 2 APPLIANCES CIRCUITS IN KITCHEN 20 AMP 210-52 ALL KITCHEN RECEPTACLES TO BE GFCI PROTECTED 210-8 JBATH GFCI TO BE ON IT'S OWN CIRCUIT 20 AMP 210-52 NEED DISCONNECTING MEANS FOR WATER HEATER 422 DERATE CONDUCTORS IN CONDUIT 310-15 NEED GAS BOND 250-104 |