Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 02/16/2001 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 02/15/2001 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/1. GAS PACK CONDENSATION LINE CANNOT BE INSTALLED BY DRILLING ABS WASTE VENT. INSTALL A SANITARY T AND REDUCER ON WASTE VENT FOR CONDENSATE CONNECTION. ELECTRIC GFCI OUTLET LEFT OF SINK WIRED INCORRECTLY HOT WHEN TRIPPED. |
| 02/14/2001 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999* |
| 02/12/2001 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999* |
| 02/09/2001 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/1. WATER HEATER MUST BE IN AN ENCLOSURE. 2. GAS LINE TO W/H MUST BE SUPPORTED AT 6' O.C. 3. IMPROPER GAS SHUT OFF VALUE ON W/H MUST HAVE A HANDLE. 4. GAS PACK NOT INSTALLED. 5. ELECT NOT ON. |