Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 02/12/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 09/18/2000 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/1. FIRE BLCOK FURR OUTS AT EAST WALL ALL ELSE OK TO INSULATE AND DRYWALL. DO NOT COVER FURR OUT. |
| 08/31/2000 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/1. FIRE BLOCK ALL FURR OUT AREAS AND DROP CEILINGS. 2. INSULATE MECHANICAL "Y" S. 3. EXISTING WALL BREAK THRU NOT COMPLETE DOOR REQUIRES 2 2 X 6 HEADER W POSTS. 4. BATHROOM GFCI CIRCUIT/OUTLET CANNOT HAVE ANY OTHER LIGHTS OR OUTLET ON THAT CIRCUIT. 5. YOU MUST HAVE 2 SEPERATE KITCHEN COUNTER CIRCUITS. 6. I MUST HAVE THE NEW INSPECITON CARD FOR THE NEW PERMIT. 7. NEED WATER PRESSURE TEST ON PLUMBING. |