Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T00CM02698
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/12/2001 | FRAMING | Approved | IVRS - Inspection 0000* | |
09/18/2000 | FRAMING | Denied | IVRS - Inspection 0999*/1. FIRE BLCOK FURR OUTS AT EAST WALL ALL ELSE OK TO INSULATE AND DRYWALL. DO NOT COVER FURR OUT. | |
08/31/2000 | FRAMING | Denied | IVRS - Inspection 0999*/1. FIRE BLOCK ALL FURR OUT AREAS AND DROP CEILINGS. 2. INSULATE MECHANICAL "Y" S. 3. EXISTING WALL BREAK THRU NOT COMPLETE DOOR REQUIRES 2 2 X 6 HEADER W POSTS. 4. BATHROOM GFCI CIRCUIT/OUTLET CANNOT HAVE ANY OTHER LIGHTS OR OUTLET ON THAT CIRCUIT. 5. YOU MUST HAVE 2 SEPERATE KITCHEN COUNTER CIRCUITS. 6. I MUST HAVE THE NEW INSPECITON CARD FOR THE NEW PERMIT. 7. NEED WATER PRESSURE TEST ON PLUMBING. |