Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 09/15/2000 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 09/06/2000 |
EXT METAL CLIPS/EXT SHEATHING |
|
Partial Approval |
IVRS - Inspection 0000*/1. PROVIDE 3/8" OSB OVER ALTERNATE SHEAR PANEL NORTH SIDE. 2'-8" MIN. SEE PLAN. 2. PROVIDE 4'-0"-3/8 OSB AT EAST CORNER. NAILING 6" ON EDGE AND 12" IN FIELD. 3. COMPLETE FRAMING AT A/C. 4. NAIL OFF HPAHD 22 AT SHEAR WALL. 5. OK TO CONTINUE PROVIDE REVISIONS TO ELIMINATE 1/2 OSB SHEATING EXTERIOR WALLS AND ELIMINATING 5040 WINDOW EAST SIDE BY FINALS. |