Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T00CM02627

Parcel: 116025750


Addresses:

2620 W AIDEN ST


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T00CM02627

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
09/15/2000 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
09/06/2000 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/1. PROVIDE 3/8" OSB OVER ALTERNATE SHEAR PANEL NORTH SIDE. 2'-8" MIN. SEE PLAN. 2. PROVIDE 4'-0"-3/8 OSB AT EAST CORNER. NAILING 6" ON EDGE AND 12" IN FIELD. 3. COMPLETE FRAMING AT A/C. 4. NAIL OFF HPAHD 22 AT SHEAR WALL. 5. OK TO CONTINUE PROVIDE REVISIONS TO ELIMINATE 1/2 OSB SHEATING EXTERIOR WALLS AND ELIMINATING 5040 WINDOW EAST SIDE BY FINALS.