Inspection Status: Correction Required
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 06/13/2000 |
PLUMBING - INTERMEDIATE |
|
Correction Required |
ADDTL COMMS - 1. WASTE AND VENT SYSTEM OK 2. OVERHEAD WATER DISTRIBUTION OK 3. OK TO DRYWALL |
| 06/06/2000 |
PLUMBING - INTERMEDIATE |
|
Correction Required |
ADDTL COMMS - 1. WASTE AND VENT SYSTEM OK 2. P.O.C. OF NEW BLDG DRAIN TO EXSISTING BLDG. DRAIN HAS 3 TEST TEE IN LINE. THERE CAN BE NO THREADED FITTINGS BELOW SLAB. REMOVE TEST TEE AND CONNECT SOLID. 3. OK TO BACKFILL TRENCH UP TO P.O.C. 4. NOTE: WILL REQUIRE REVISED AND APPROVED DRAWING ON WASTE AND VENT SYSTEM PRIOR TO FINAL |
| 06/06/2000 |
PLUMBING - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection 0000* |