Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 04/30/2001 |
ELECTRIC - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000* |
| 02/23/2001 |
ELECTRIC - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*/1. GARAGE ELECTRIC SUB PANEL MUST HAVE A MASTER DISCOUNT CIRCUIT BREAKER. 2. GARGE SUBPANEL MUST HAVE AN ISOLATED NEUTRAL BAR AND A BONDED GROUND BAR. 3. GARAGE ELECTRIC OUTLETS MUST BE GROUND FAULT CIRCUIT PROTECTED. 4. MAKE UP GROUND WIRES IN LIGHT BOXES ON CEILING AND SECURE WITH MECHANICAL FASTENER. 5. GROUND ALL LIGHT SWITCHES WITH PIG TAIL TO GROUND WIRE. 6. GROUND ALL METAL ELECTRIC BOXES LOCK NUTS ARE NO LONGER ALLOWED FOR GOUNDING/BONDING. |