Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 09/27/2000 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 09/26/2000 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/1. PROVIDE MIN. 30" X 30" ACCESS FROM ATTIC OPENING TO FURNACE. 2. SECURE GAS LINES AT ATTIC FURNACE. 3. FILL IN WALKWAY WEST CATWALK COMPLETELY (ATTIC FURNACE). 4. CUT SEWER C.O.'S TO GRADE. |
| 09/25/2000 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/1. INSTALL 90 DEGREE ELBOW CONDENSATE DRAIN TERMINATION AT EXTERIOR NEAR A.C. LOCATION (BOTH ENDS OF HOUSE). 2. BACKFILL AROUND SEWER C.O'S, COMPLETE GRADING 3. CUT C.O.'S TO GRADE. 4. MAINTAIN 1" AIR GAP WASHER DRAIN FOR H2O FOR SOFTNER. 5. LADDER ACCESS TO ATTIC 6. NEED APPROVALS ON ALL INTER. INSPECTIONS. |