Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 10/17/2000 |
FRAMING |
|
Approved |
IVRS - Inspection 0000*/ |
| 10/13/2000 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/1. PROVIDE STRAPS AT OVER NOTCHED DBL TOP PLATE (AT GAS). 2. HOT WATER FLUE NOT PER 805.1 UMC. 3. DRAFT STOP MASTER CLOSET AND W/C. 4. SUPPORT 90 DEGREE VTR AT MASTER W/C. 5. NEED EXHAUST AT MASTER--PER PENDING REVISE. 6. H25 LEDGER, BOLT AND SHEET COLUMNS, RBP4 PARAPET--SEE MATT. |
| 09/19/2000 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/1. PROVIDE REVISION TO SITE PLAN FOR EXTENDED PATIO PORCH. 2. PROVIDE DETAILS FOR FRAMING OF PATIO PORCH WITH BUILT-UP BEAM AND COLUMN DETAIL. DO NOT LATH UNTIL INSPECT/REVISION COMPLETE. (CURRENTLY 2 X 8 AT 19'0" ON 16" CENTERS) 3. PATIO POST NOT PER PLAN, NO CONNECTION OF PARAPETS TO BARGE RAFTERS. 4. AS PER PHONE CALL TO PLAN CHECK-2 X 8' ARE OVER SPANNED--STOP WORK ON PATIO UNTIL APPROVED REVISIONS AQUIRED. 5. NO APPROVED TRUSS CALC'S ON SITE AT INSPECTION. (THERE ARE 3 POINT BEARING TRUSSES.) 6. PROVIDE 1/2" AB'S WITHIN 12" OF SPLIT SOLE PLATES. 7. NO TEST ON PLUMBING. 8. NO REVISION FOR FURNACE IN ATTIC YET. NO C & U TO FURNACE IN ATTIC. 9. ROUGH PLUMBING AT JACCUZI NOT COMPLETE. 10. SUPPORT 90 DEGREE UTR'S. 11. A/C ELECTRIC NOT COMPLETE. 12. PROVIDE REVISION TO MASTER BATH WITH MECHANICAL EXHAUST DUCTING. |